Features & Applications
1. Aluminum alloy material,sealed with glue to IP65 protection level.
2. Integral Structure and easy installation.
3. Application: packing scale.
Specifications
Maximum capacity
Minimum load cell verification interval
kg
50
20
100
20
200
50
300
50
500 100
750
100
Item
Unit
Parameter
Accuracy class to OIML R60
C2
C3
Maximum capacity(Emax)
kg
50,100,200,300,500,750
Sensitivity(Cn)/Zero balance
mV/V
2.0±0.2/0±0.1
Temperature effect on zero balance
% of Cn/10K
±0.0175
±0.0140
Temperature effect on sensitivity
% of Cn/10K
±0.0175
±0.0140
Hysteresis error
% of Cn
±0.02
±0.0150
Non-linearity
% of Cn
±0.0270
±0.0167
Creep over 30 mins
% of Cn
±0.0250
±0.0167
Eccentric error
%
±0.0233
Input & Output resistance
Ω
382±15 & 352±3
Nominal range of excitation voltage
V
5~15
Insulation resistance at 50V DC
MΩ
≥5000
Service temperature range
℃
-20~+50
Safe load limit & Breaking load
%of Emax
120&200
Protection class according to EN60 529
IP65
Measuring material
Alloy steel
Maximum platform size
mm
800x800
Deflection at Emax
mm
<0.6
Weight
kg
4.3
4.5
Cable diameterΦ5mm length
m
3
Tightening torque
N.m
35