Specificaions
Material:Measuring element
Cable fitting
Cable sheath
Alloy steel
Nickel-plated brass
PVC
Item
Unit
Parameter
Accuracy class to OIML R60
C2
C3
Maximum capacity(Emax)
t
1,2
Minimum LC verification interval
%of Emax
0.0200
0.0100
Sensitivity(Cn)
mV/V
2.0±0.002
Zero balance
mV/V
0±0.03
Temperature effect on zero balance
%of Cn/10K
±0.02
±0.0170
Temperature effect on sensitivity
%of Cn/10K
±0.02
±0.0170
Hysteresis error
%of Cn
±0.0270
±0.0180
Non-linearity
%of Cn
±0.0250
±0.0167
Creep over 30 min
%of Cn
±0.030
±0.0167
Input&output resistance
Ω
400±10&352±3
Nominal range of excitation voltage
V
5~15
Insulation resistance at 50V DC
MΩ
≥5000
Service temperature range
℃
-30~+70
Safe load limit & breaking load
% of Emax
150 & 300
Protecting class according to EN60 529(IEC529)
IP67
Cable diameter & length
mm&m
6 & 3